Description
Cisco Nexus7000-4Slot Dubai
The Cisco Nexus7000-4Slot Dubai chassis is equipped with two I/O module slots, supporting a capacity of up to 96 x 1 and 10 Gigabit Ethernet ports, 12 x 40 Gigabit Ethernet ports, and 4 x 100 Gigabit Ethernet ports. This configuration caters to the requirements of small to medium-sized data centers, co-locations, access- and aggregation-layer deployments, high-speed core deployments, and smaller operational zones. For enhanced reliability, the Cisco Nexus7000-4Slot Dubai chassis features two dedicated supervisor slots, ensuring full redundancy and high availability.
Notably, the 4-slot chassis eliminates the need for fabric modules. The local I/O module fabrics are interconnected back to back, forming a two-stage crossbar that links the I/O modules and the supervisor engines. The backplane capacity is directly influenced by the installed I/O modules.
Features
High Availability
- The Cisco Nexus 7000 4-Slot Switch provides :
- Fully redundant system architecture with dual supervisors, redundant power supplies, and fans
- Lossless, non-disruptive In-Service Software Upgrades (ISSUs) for zero service downtime
- Graceful system operations to minimize the effect of upgrades and other maintenance
Scalability
Protect your infrastructure investments with the following features :
- 92 Tbps of switching capacity to scale for future growth demands
- Highly scalable modular NX-OS features such as Fabric Path and Fabric Extender (FEX) technology
Transport Flexibility
This switch offers transport flexibility with :
- Support for 1, 10, 40, and 100 Gigabit Ethernet interfaces
- Optics options from short-range to long-range DWDM
- Fibre Channel over Ethernet (FCoE) for LAN and SAN consolidation
In addition, you get extensive Cisco Data Center Interconnect features, including :
- Overlay Transport Virtualization
- Locator ID Separation Protocol
- Multiprotocol Label Switching (MPLS)
Operational Efficiency
- Enhance your data center with increased operational efficiency, including :
- Single software image with a consistent NX-OS feature set across the Cisco Nexus 7000 Series
- Virtual Device Context (VDC) for efficient resource utilization
- Simplified management with choices of Simple Network Management Protocol (SNMP), XML API, and Cisco Data Center Network Manager
- Integrated alerts with Cisco IOS Embedded Event Manager (EEM)
Integrated cable management system
designed to support the cabling requirements of a fully configured system at either or both sides of the switch, allowing outstanding flexibility. All system components can easily be removed with the cabling in place, providing ease of maintenance tasks with little disruption.
Easy to Operate
A series of LEDs at the top of the chassis provide a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.
Convenient Design
Cisco Nexus7000-4Slot Dubai has purpose-built optional front-module door provides protection from accidental interference with both the cabling and modules installed in the system. The transparent front door allows easy observation of cabling and module indicators and status lights without any need to open the doors, reducing the likelihood of faults caused by human interference. The door supports a dual-opening capability for flexible operation and cable installation while fitted. The door can easily be completely removed for both initial cabling and day-to-day management of the system.
Energy-Efficient Design
The Cisco Nexus7000-4Slot Dubai uses power supplies that are up to 90 percent efficient, so less power is wasted as heat, and more power is available for the system to use than with typical power supplies. The fan modules in the chassis adjust to compensate for changing thermal characteristics.
Specifications
Item | Cisco Nexus 7000 4-Slot Switch | Cisco Nexus 7000 9-Slot Switch | Cisco Nexus 7000 10-Slot Switch | Cisco Nexus 7000 18-Slot Switch |
Product compatibility | Supports all Cisco Nexus 7000 Series Supervisor and I/O modules except the following :
N7K-SUP1 N7K-M132XP-12 N7K-M148GS-11 N7K-M148GT-11 N7K-F132XP-15 Does not use fabric modules |
Supports all Cisco Nexus 7000 Series Supervisor and I/O modules
Supports Fabric2 modules Does not support Fabric1 modules |
Supports all Cisco Nexus 7000 Series Supervisor and I/O modules
Supports Fabric1 and Fabric2 modules |
Supports all Cisco Nexus 7000 Series Supervisor and I/O modules
Supports Fabric1 and Fabric2 modules |
Max local switching capacity | 600 Gbps | 600 Gbps | 600 Gbps | 600 Gbps |
Max inter-slot switching capacity | 440 Gbps | 550 Gbps | 550 Gbps | 550 Gbps |
Software compatibility | Cisco NX-OS Software Release 6.1(2) or later | Cisco NX-OS Software Release 5.2 or later | Cisco NX-OS Software Release 4.0 or later | Cisco NX-OS Software Release 4.1 or later |
Options | Lockable front module door | Lockable front module door | Air filter
Lockable front module doors |
Lockable front module door |
Performance | 1.44 billion packets per second (bpps) (IPv4 unicast) in combination with supervisor module and built-in fabric | 5.04 bpps (IPv4 unicast) in combination with supervisor and fabric modules | 5.76 bpps (IPv4 unicast) in combination with supervisor and fabric modules | 11.5 bpps (IPv4 unicast) in combination with supervisor and fabric modules |
Reliability and availability | Online insertion and removal (OIR) of all redundant components : supervisor modules, power supplies, and fan trays | OIR of all redundant components : supervisor and fabric modules, power supplies, and fan trays | OIR of all redundant components : Supervisor and fabric modules, power supplies, and fan trays | OIR of all redundant components : supervisor and fabric modules, power supplies, and fan trays |
MIBs | Supports Simple Network Management Protocol (SNMP) Versions 3, 2c, and 1 (see Cisco NX-OS Software release notes for details about specific MIB support) | Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support) | Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support) | Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support) |
Network management | Cisco Data Center Network Manager (DCNM) 6.1.(2) or later | Cisco DCNM 5.2 or later | Cisco DCNM 4.0 or later | Cisco DCNM 4.1 or later |
Programming interfaces | XML
Scriptable command-line interface (CLI) Cisco DCNM 6.1(2) web services |
XML
Scriptable CLI Cisco DCNM 5.2 web services |
XML
Scriptable CLI Cisco DCNM 4.0 web services |
XML
Scriptable CLI Cisco DCNM 4.1 web services |
Physical specifications | Usable rack space : 7RU
4-slot chassis : 2 dedicated supervisor modules and 2 I/O modules 4 power supply slots Dimensions (H x W x D) : 12.2 x 17.3 x 24 in. (30.9 x 43.9 x 61 cm) Chassis depth including cable management and chassis doors is 29.6 in. (75.2 cm) Unit is rack mountable in a standard 19-inch (482.6-mm) Electronic Industries Alliance (EIA) rack Weight Chassis only : 45 lb. (20 kg) Fan Tray : 25 lb (11.3 kg) Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies Supports up to 6 chassis stacked in a 42RU rack |
Usable rack space : 14RU
9-slot chassis : 2 dedicated supervisor modules and 7 I/O modules 5 fabric module slots 2 power supply slots Dimensions (H x W x D) : 24.5 x 17.3 x 24 in. (62.2 x 43.9 x 61 cm) Chassis depth including cable management and chassis doors is 29 in. (73.7 cm) Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack Weight Chassis only : 100 lb. (45 kg) Fabric Module : 5 lb (2.3 kg) Fan Tray : 25 lb (11.3 kg) Supports 6-kW and 7.5-kW AC and DC power supplies Supports up to 3 chassis stacked in a 42RU rack |
Usable rack space : 21RU
10-slot chassis : 2 dedicated supervisor modules and 8 I/O modules 5 fabric module slots 3 power supply slots Dimensions (H x W x D) : 36.5 x 17.3 x 33.1 in. (92.7 x 43.9 x 84.1 cm) Chassis depth including cable management and chassis doors is 38 in. (96.5 cm) Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack Weight Chassis only : 200 lb. (90 kg) Fabric Module : 4 lb (1.8 kg) System Fan Tray : 20 lb (9.1 kg) Fabric Fan Tray : 5 lb (2.3 kg) Supports 6-kW and 7.5-kW AC and DC power supplies |
Usable rack space : 25RU
18-slot chassis : 2 dedicated supervisor modules and 16 I/O modules 5 fabric module slots 4 power supply slots Dimensions (H x W x D) : 43.5 x 17.3 x 33.1 in. (110.5 x 43.9 x 84.1 cm) Chassis depth including cable management and chassis doors is 38 in. (96.5 cm) Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack Weight Chassis only : 187 lb. (85 kg) Fabric Module : 7.5 lb (3.4 kg) Fan Tray : 25.8 lb (11.7 kg) Supports 6-kW and 7.5-kW AC and DC power supplies |
Environmental specifications | Airflow direction : Side to rear
Operating temperature : 32 to 104°F (0 to 40°C) Operational relative humidity : 5 to 90%, non-condensing Operating altitude : -500 to 13,123 ft. (agency certified 0 to 6500 ft.) Seismic : Zone 4 per GR63 Floor loading : 42 lb. per sq. ft. Operational vibration GR63, Section 5.4.2 ETS 300 019-1-3, Class 3.1, Section 5.5 Storage altitude : -1000 to 30,000 ft. Storage temperature : -40 to 158°F (-40 to 70°C) Storage relative humidity : 5 to 95%, non-condensing Heat dissipation : Maximum 3500W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
Airflow direction : Side to side
Operating temperature : 32 to 104°F (0 to 40°C) Operational relative humidity : 5 to 90%, non-condensing Operating altitude : -500 to 13,123 ft. (agency certified 0 to 6500 ft.) Seismic : Zone 4 per GR63 Floor loading : 104 lb. per sq. ft. Operational vibration GR63, Section 5.4.2 ETS 300 019-1-3, Class 3.1, Section 5.5 Storage altitude : -1000 to 30,000 ft. Storage temperature : -40 to 158°F (-40 to 70°C) Storage relative humidity : 5 to 95%, non-condensing Heat dissipation : Maximum 7500W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
Airflow direction : Bottom front of chassis to top back
Operating temperature : 32 to 104°F (0 to 40°C) Operational relative humidity : 5 to 90%, non-condensing Operating altitude : -500 to 13,123 ft. (agency certified 0 to 6500 ft.) Seismic : Zone 4 per GR63 Floor loading : 190 lb. per sq. ft. Operational vibration GR63, Section 5.4.2 ETS 300 019-1-3, Class 3.1, Section 5.5 Storage altitude : 1000 to 30,000 ft. Storage temperature : -40 to 158°F (-40 to 70°C) Storage relative humidity : 5 to 95%, non-condensing Heat dissipation : Maximum 12,000W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
Airflow direction : Side to side
Operating temperature : 32 to 104°F (0 to 40°C) Operational relative humidity : 5 to 90%, non-condensing Operating altitude : -500 to 13,123 ft. (agency certified 0 to 6500 ft.) Seismic : Zone 4 per GR63 Floor loading : 190 lb. per sq. ft. Operational vibration GR63, Section 5.4.2 ETS 300 019-1-3, Class 3.1, Section 5.5 Storage altitude : 1000 to 30,000 ft. Storage temperature : -40 to 158°F (-40 to 70°C) Storage relative humidity : 5 to 95%, non-condensing Heat dissipation : Maximum 18,000W per chassis (actual dissipation will be lower, depending on the chassis configuration) |